Common problem

Injection molding machine common fault treatment method

2024-10-07 09:33:09 Injection molding machine

First, the oil pump motor and oil pump start, but not pressure.

1. The proportional valve on the oil pump is loose or the coil is burned - check whether the proportional pressure valve is energized.

2. Impurities block the oil port of the proportional pressure valve on the oil pump -- remove the proportional pressure valve to 

remove impurities.

3. The pressure oil is unclean, the debris accumulates on the surface of the oil filter, preventing the pressure oil from entering the 

pump - clean the oil filter and replace the pressure oil.

4. Oil leakage inside the oil pump, caused by too long use, internal loss or pressure oil unclean damage - repair or replace the oil 

pump.

5. Oil spillage barrels, oil pipes and joints - eliminate leakage areas.

6. Oil business card printing dead - check whether the oil spool activity is normal.

injection mould


Second, the melting tube temperature can not be controlled

1. If the temperature cannot be controlled, check whether the contact of the electric heating contactor is sticky, and whether the wire of the thermocouple is loose or damaged.

2. If the temperature cannot rise, check whether the electric heating air switch in the electric box is off, whether the contactor and relay are drawn, whether there is voltage, whether the insurance is burned out, and whether the heating ring is burned out.

3. Check whether the thermometer is damaged.


Three, no mold locking

1. Whether the front opening safety door has been closed, whether the stopper of the safety door has been pressed and loosened 

by the safety door, and whether the wiring is loose or damaged.

2. The mode-locked solenoid coil may have moved inside the valve and stuck the spool -- clean or replace the mode-locked mold 

opening control valve.

3. Direction valve may be out of position - Clean the direction valve.

4. The thimble cannot be returned to reset -- check whether the thimble works normally.

5. Check whether the origin of the mode-locking and mode-opening electronic ruler of the computer controller has changed and 

whether the mode-locking position has terminated.

6. Check whether the pressure gauge works.

7. Press the mode-locking key to see whether the display displays mode-locking signals or other signals and alarms.

8. Check whether the position, speed and pressure of the mold lock are adjusted normally.

9. Check whether the clamping piston rod is broken.


Four, do not shoot glue

1. The coil of the injection solenoid system may have been burned, or there are foreign objects entering the direction valve, and the 

valve core is stuck to move - clean or replace the injection valve.

2. The pressure is too low -- adjust the pressure of the high jet glue.

3. The temperature of injection molding is too low - adjust the thermometer to increase the temperature to the required point, such 

as adjusting the thermometer still can not increase the temperature, check whether the electric heater and fuse are burned out

Or loose break, if broken, timely replacement.

4. The injection combination valve opening system connection is loose or poor contact - the combination switch wire connector is 

properly connected.


Fifth, the glue screw rotates, but the rubber material does not enter the barrel

1. The melt back pressure is too high, the back pressure valve is damaged or improperly adjusted -- adjust or replace the melt back 

pressure valve.

2. Insufficient water transport, so that the temperature is too high, so that the rubber particles into the screw is blocked - adjust the 

water transport, take out the bonded rubber block. See if the water conveyor is blocked or has no cooling water

3. There is no material in the bucket - add material.

4. Whether the melt tube temperature is too high.


Six. The shooting platform does not move

1. The moving limit travel switch of the shooting platform is pressed by the adjusting ram - adjust.

2. The coil of the shooting platform moving solenoid valve may be burned or there are foreign objects entering the direction valve 

stuck in the spool to move - clean or replace the solenoid valve.

3. Check the forward speed of the shooting platform and whether the pressure is improperly adjusted.

4. Check the 1/0 board, the direction valve output voltage (DC+24V) is normal, if not normal, check the corresponding output 

transistor or relay is damaged.

5. Press the station key to check whether the computer display displays the signal in front of the station, or other signals and alarms.

6. Check whether the pressure gauge works.

injection mould


Home
Product
News
Contact
亚洲精品中文字幕乱码三区| 精品久久久久久久人妻九色欲av| 97PORM国内自拍视频| 国产日韩无码一区二区三区久久区| 欧美天天综合色影久久精品| 精品偷自拍另类在线观看| 国产女人爽的流水毛片| 看久久久久A级毛片免费| 99久久综合狠狠| 国产精品| 亚洲欧美日韩久久精品第一区| 久久综合国产乱子伦精品免费| 国产福利电影一区二区三区| 亚洲伊人成色综合国产高清精品毛片| 久久久久青草大香综合精品| 亚洲顶级片在线免费播放| 久久精品亚洲一区二区三区浴池| 少妇一级婬片免费放真人一级黄毛片| 性色生活片在线观看| 久久毛片免费看一区二区三区| 免费无码黄动漫在线观看| 成人H动漫精品一区二区无码| 天天躁夜夜躁狠狠综合2020| 4399视频在线观看免费完整版| 野花香日本大全免费观看| 99精品人妻少妇一区二区| 学生被强奷到高潮喷水在线观看| 国产亚洲精品久久久久的角色| 亚洲中文有码字幕日本第一页| 女自慰喷潮免费观看www久久| 欧洲无码A片在线观看| 亚洲成AV人片一区二区密柚| 日韩人妻无码精品无码中文字幕| 精品欧美日韩在线视频| 精品视频在线观看一区二区| 免费人成在线观看网站| 国产超爽人人爽人人做| 久久av网站一区二区三区| 日韩一区二区三区免费观看女同| 国产性色欧美亚洲黄片| 日日碰狠狠添天天爽超碰97久久| 国产精品伦一区二区三级视频|